ENERGY CERTIFICATION AND ENERGY AUDIT OF HIGHER EDUCATION AS A METHODOLOGICAL TOOL TO IMPROVE THE ENERGY EFFICIENCY OF THE UNIVERSITY

BACKGROUND AND OBJECTIVES. Improving the energy performance of buildings is one of the least expensive ways to reduce energy consumption and greenhouse gas emissions. Building energy performance certification increases public knowledge about energy conservation and allows consumers and other decision makers to compare buildings based on their lifetime performance. In addition, energy performance certifications are an incentive for owners to improve the efficiency of existing buildings.METHODS. It is proposed to use in the process of energy certification and energy audit of university buildings collection and evaluation of basic information (including information about local climate, method of use, value of thermal conductivity coefficient and building envelope area, orientation) to determine the level of energy efficiency of the building on a generally accepted scale. In the Certificate of energy efficiency to take into account the calculated results from the assessment of the energy performance of the building.FINDINGS. It is suggested that the results of the energy certification of university buildings be presented in a simple, clear form, to ensure clarity, ease of use and comparability. For the energy certification of university buildings, a comparative labeling from A to G is proposed for use. The scale, on which the current national building standard is at "C," provides ample room for improving the rating of both new and existing buildings. If necessary, the scale should be expanded to add a label such as A1, A2, or A+, A++ when it comes to high-performance buildings.CONCLUSION. Accurate and reliable energy performance certification is a necessary foundation that will help ensure consumer confidence and the success of the certification program. The certification program must be clearly coordinated to ensure a smooth transition of the construction industry to the new rules.

Energy Assessment of a Combined Cycle Power Plant through Empirical and Computational Approaches: A Case Study

Energy management on the demand side is an important practice through which to address the challenge of energy shortage. In Pakistan, power plants have no specific energy management practice and a detail energy audit is normally observed as a one-time estimation that does not give significant information. In this study, an energy audit of a combined-cycle gas turbine power station was conducted and empirical data were compared with those obtained through a model developed in ASPEN, a simulation software that forecasts process performance. Next, an optimization tool was used to modify the ASPEN results and a comparison was drawn to estimate the amount of energy saved. It was found that compressor power consumption can be decreased up to 14.68% by increasing the temperature of compressed air from 320.2 °C to 423.79 °C for gas turbines. The output of gas turbines can be enhanced up to 13.5% and 21.4% with modelled and optimized data, respectively, using a multistage air compressor and multistage expansion. The calculated efficiency of the steam turbine was found to be 30.4%, which is 27.61% less than that of its designed efficiency. Steam turbine efficiency can be increased by 5% using a variable-speed water pump, leading to an estimated energy-saving potential of 8–9%. The combustion efficiency of gas turbines is not only important for higher turbine power output but also for better steam generation through heat-recovery steam generators in case of combined-cycle operations. The overall steam turbine efficiency is estimated to have increased by 19.27%, leading to a 12.68% improvement in combined efficiency.

From Audits to Projects: Evaluating New York State Policy to Encourage Home Retrofit Projects

This research explores socio-spatial characteristics of home retrofit projects in New York State and their association with the state’s free home energy audit program. Prior work by the authors found that zip codes with more elder individuals and higher levels of education are more likely to undertake an energy audit; it was also found that higher incomes may be negatively correlated with audit decisions. Less understood is the follow-up decision after an audit to undertake a retrofit. From a policy and climate perspective, the actionable retrofit decision is far more impactful than the informational audit, making it an important area of further research. This work examines this understudied area using a combination of datasets, including census data, American Community Survey (ACS) data, and retrofits data provided by the New York State Energy Research and Development Authority (NYSERDA). Findings indicate that many of the same socioeconomic characteristics that predict audits are influential in retrofit projects as well (age, education, higher home values). A strong statistical relationship was found between audits per capita and subsequent retrofit projects, which is to be expected, as NYSERDA requires audits of residents desiring efficiency retrofits. However, this also indicates that the role of the audit in information transfers may be highly influential in encouraging home energy efficiency projects. This finding underscores the policy importance of offering low- or no-cost energy audit incentives to encourage greater participation in home retrofit programs.

Energy saving analysis of air fan motor in power plant boiler controlled by variable frequency drive

A reporting of Energy Audit in 2018 by LEMTEK UI has reported that air fan system currently used in Power Plant of PLTU Tanjung Jati B Jepara is inefficient, energy efficiency in FDF is only 32% and PAF efficiency is 49.01%. Inefficiency of the air fan system is an impacted there are waste of electric energy amount of 13,352,929 KWh (13,35 GWh) a year with a financial loss of IDR 13,352,929,140. To overcome this condition, variable frequency drive (VFD) is installed which adjusted air flow as needed so that energy waste can be reduced. MATLAB simulation is proposed to analyze the VFD method. The result shows that by using VFD, 8,233,573.444 KWh (8.45 GWh) can be saved a year. Total cost benefits are IDR 8,233,573,444 as 32.1% of saving cost. Efficiency of FDF is 72.57 % and PAF is 66.84%.

Energy Efficiency Initiatives for A Hospital Building in Malaysia

In the past decades, research about energy consumption reduction has become a trend due to concern of energy wastage that leads to the negative impact on the environment. Commercial sector produces higher energy consumption compared to other sectors in Malaysia and hospital building is one of the highest energy consumptions in the commercial sector. Continuous operation time and complexity of engineering system are some of the reasons for high energy consumptions in hospital buildings that leads to high energy costs. This study examines the electricity load apportioning for a hospital building in Selangor, Malaysia through a detailed energy audit. From the energy audit, several Energy Efficiency Initiatives (EEI) were identified in reducing the energy usage in hospital: room temperature control, efficient lighting system, efficient unit for Air-Conditioning Split Unit (ACSU) and Variable Speed Drive (VSD) installation. The EEIs is expected to produce a total electricity saving of 1,250,692 kWh/year, equivalent to a cost saving of RM 421, 706/year and total emission reduction of 869 tonnes CO2 per year.

Integration of Projects Enhancing Productivity Based on Energy Audit Data in Raw Milk Production Sector — a Case Study in Turkey

Energy audit implementation according to iso 50002 standard in a bakery company, validation and calibration of dynamic energy models: energy audit of a public building.

Abstract Detailed buildings energy audits require dynamic simulation models based on hourly input data. This paper presents the calibration and validation of an office building energy model for the heating and cooling services. Simulation are carried out by DesignBuilder software. Measured hourly heating and cooling energy supplied by the generation system are used for the calibration of the model. Employee behaviour with reference to occupancy profiles and indoor temperature settings is also considered. A good agreement between measured and simulated data is obtained for both heating and cooling seasons.

Electrical power supply consumption in education sector and energy audit: Case study of University of Jos

Electricity supply has been identified as the key constraint to industrialization and economic development in Nigeria. The unbundling of the power sector was aimed at boosting electricity supply, this effort has yielded some appreciable results, but not very significant. As a result of the low power generation and distribution, Nigeria’s federal government is working towards solving the prevailing problems of inadequate power in some key sectors by building power generating plants in some of the institutions of learning in the country. This paper looks at the determinants of electrical energy consumption and electrical energy audit, a case study of the University of Jos. The load profiles demand survey, load demand forecast and other important factors were investigated. The result revealed that there is available power of 22–23 hours from the national grid and the balance 1–2 hours of power is supplied by the generating sets, good savings in the cost of diesel and maintenance. An annual excess of 2,199,900 kWH is enjoyed by the university over the national per capita power consumption.

Implementation Analysis for Energy Audit Process at MSRTC Bus Station- A Review Research

Energy audit consists of survey, analysis and inspection of the energy flow in the system. Its aim is to find the scope of energy conservation by implementing energy saving procedures without affecting the outputs of the system. One such system which can conserve energy is MSRTC bus station which requires a lot of energy consumption for its everyday activities. Energy audit plays a significant role in finding opportunities to save energy and reduce electricity bills. Energy audit recommends ways to save energy consumption by some changes in the system with emphasis on that there are no negative output by the changes made. The Energy Audit would provide a positive orientation to the energy cost reduction along with preventive maintenance and quality control programs which are vital for production and utility activities.

Export Citation Format

Share document.

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • View all journals
  • Explore content
  • About the journal
  • Publish with us
  • Sign up for alerts
  • Published: 30 March 2020

The impact of mandatory energy audits on building energy use

  • Constantine E. Kontokosta   ORCID: orcid.org/0000-0003-4831-9996 1 ,
  • Danielle Spiegel-Feld 2 &
  • Sokratis Papadopoulos 3  

Nature Energy volume  5 ,  pages 309–316 ( 2020 ) Cite this article

3391 Accesses

38 Citations

44 Altmetric

Metrics details

  • Environmental social sciences
  • Environmental studies
  • Social policy

Cities are increasingly adopting energy policies that reduce information asymmetries and knowledge gaps through data transparency, including energy disclosure and mandatory audit requirements for existing buildings. Although such audits impose non-trivial costs on building owners, their energy use impacts have not been empirically evaluated. Here we examine the effect of a large-scale mandatory audit policy—New York City’s Local Law 87—on building energy use, using detailed audit and energy data between 2011 and 2016 for approximately 4,000 buildings. This specific policy context, in which the compliance year is randomly assigned, provides a unique opportunity to explore the audit effect without the self-selection bias found in studies of voluntary audit policies. We find energy use reductions of approximately –2.5% for multifamily residential buildings and –4.9% for office buildings. The results suggest that mandatory audits, by themselves, create an insufficient incentive to invest in energy efficiency at the scale needed to meet citywide carbon-reduction goals.

This is a preview of subscription content, access via your institution

Access options

Access Nature and 54 other Nature Portfolio journals

Get Nature+, our best-value online-access subscription

24,99 € / 30 days

cancel any time

Subscribe to this journal

Receive 12 digital issues and online access to articles

111,21 € per year

only 9,27 € per issue

Buy this article

  • Purchase on Springer Link
  • Instant access to full article PDF

Prices may be subject to local taxes which are calculated during checkout

research paper on energy audit

Similar content being viewed by others

research paper on energy audit

Bringing rigour to energy innovation policy evaluation

research paper on energy audit

A multi-country meta-analysis on the role of behavioural change in reducing energy consumption and CO2 emissions in residential buildings

research paper on energy audit

Social and technical differentiation in smart meter rollout: embedded scalar biases in automating Norwegian and Portuguese energy infrastructure

Data availability.

All data, except LL87 data, are available through the NYC Open Data Portal at https://opendata.cityofnewyork.us/ . LL87 data are available upon reasonable request, and with permission, from the NYC Mayor’s Office of Sustainability. The data that support the plots within this Article and other findings of this study can be obtained from the NYC Mayor’s Office of Sustainability or the authors, upon permission from the NYC Mayor’s Office of Sustainability who own the data.

Code availability

Any applicable code relevant to the findings is available from the authors upon reasonable request.

Glaeser, E. L. & Kahn, M. E. The greenness of cities: carbon dioxide emissions and urban development. J. Urban Econ. 67 , 404–418 (2010).

Google Scholar  

Inventory of New York City Greenhouse Gas Emissions (City of New York, 2017); https://www.dec.ny.gov/docs/administration_pdf/nycghg.pdf

Burr, A., Keicher, C. & Lawrence, J. Commercial Building Energy Rating and Disclosure Policies (Institute for Market Transformation, 2013).

Jaffe, A. B. & Stavins, R. N. The energy-efficiency gap What does it mean? Energy Policy 22 , 804–810 (1994).

Map: U.S. City, County, and State Policies for Existing Buildings: Benchmarking, Transparency and Beyond (Institute for Market Transformation, 2017); https://www.imt.org/resources/map-u-s-building-benchmarking-policies

LL87: energy audits & retro-commissioning NYC Mayor’s Office of Sustainability http://www.nyc.gov/html/gbee/html/plan/ll87.shtml (2020).

New York City’s Energy and Water Use 2014 and 2015 Report (City of New York, 2017); http://www.nyc.gov/html/gbee/downloads/pdf/UGC-Benchmarking-Report-101617-FINAL.pdf

Meng, T., Hsu, D. & Han, A. Estimating energy savings from benchmarking policies in New York City. Energy 133 , 415–423 (2017).

Palmer, K. & Walls, M. Using information to close the energy efficiency gap: a review of benchmarking and disclosure ordinances. Energy Effic. 10 , 673–691 (2017).

Papadopoulos, S., Bonczak, B. & Kontokosta, C. E. Pattern recognition in building energy performance over time using energy benchmarking data. Appl. Energy 221 , 576–586 (2018).

Hsu, D. How much information disclosure of building energy performance is necessary? Energy Policy 64 , 263–272 (2014).

Spiegel-Feld, D. Local Law 97: Emissions trading for buildings? NYU Law Review Online 94 , 148–168 (2019).

Chidiac, S., Catania, E., Morofsky, E. & Foo, S. Effectiveness of single and multiple energy retrofit measures on the energy consumption of office buildings. Energy 36 , 5037–5052 (2011).

Ardente, F., Beccali, M., Cellura, M. & Mistretta, M. Energy and environmental benefits in public buildings as a result of retrofit actions. Renew. Sust. Energy Rev. 15 , 460–470 (2011).

Hestnes, A. G. & Kofoed, N. U. Effective retrofitting scenarios for energy efficiency and comfort: results of the design and evaluation activities within the office project. Build. Environ. 37 , 569–574 (2002).

Ürge-Vorsatz, D., Harvey, L. D. D., Mirasgedis, S. & Levine, M. D. Mitigating CO 2 emissions from energy use in the world’s buildings. Build. Res. Inf. 35 , 379–398 (2007).

Use of Energy in the United States Explained (U.S. Energy Information Administration, 2017); https://www.eia.gov/energyexplained/index.cfm?page=us_energy_use

Nadel, S. Pathway to Cutting Energy Use and Carbon Emissions in Half (American Council for an Energy-Efficient Economy, 2016).

Bradshaw, J. L., Bou-Zeid, E. & Harris, R. H. Greenhouse gas mitigation benefits and cost-effectiveness of weatherization treatments for low-income, American, urban housing stocks. Energy Buildings 128 , 911–920 (2016).

Fulton, M. et al. United States Building Energy Efficiency Retrofits: Market Sizing and Financing Models (Deutsche Bank Climate Change Advisors, 2012).

Chidiac, S., Catania, E., Morofsky, E. & Foo, S. A screening methodology for implementing cost effective energy retrofit measures in Canadian office buildings. Energy Build. 43 , 614–620 (2011).

Im, J., Seo, Y., Cetin, K. S. & Singh, J. Energy efficiency in US residential rental housing: adoption rates and impact on rent. Appl. Energy 205 , 1021–1033 (2017).

Ryghaug, M. & Sørensen, K. H. How energy efficiency fails in the building industry. Energy Policy 37 , 984–991 (2009).

Hirst, E. & Brown, M. Closing the efficiency gap: barriers to the efficient use of energy. Resour Conserv. Recycl. 3 , 267–281 (1990).

Gillingham, K. and Palmer, K. Bridging the Energy Efficiency Gap Discussion paper 13–02 (Resources for the Future, 2013).

Kontokosta, C. E. Energy disclosure, market behavior, and the building data ecosystem. Ann. NY Acad. Sci. 1295 , 34–43 (2013).

Hope, A. J. & Booth, A. Attitudes and behaviours of private sector landlords towards the energy efficiency of tenanted homes. Energy Policy 75 , 369–378 (2014).

Elbel, B., Kersh, R., Brescoll, V. L. & Dixon, L. B. Calorie labeling and food choices: a first look at the effects on low-income people in New York City. Health Affairs 28 , w1110–w1121 (2009).

Davis, L. W. & Metcalf, G. E. Does better information lead to better choices? Evidence from energy-efficiency labels. J. Assoc. Environ. Resour. Econ. 3 , 589–625 (2016).

Newsham, G. R., Mancini, S. & Birt, B. J. Do LEED-certified buildings save energy? Yes, but. Energy Build. 41 , 897–905 (2009).

Kontokosta, C. E. A market-specific methodology for a commercial building energy performance index. J. Real Estate Finance Econ. 51 , 288–316 (2015).

Niemeyer, S. Consumer voices: adoption of residential energy-efficient practices. Int. J. Consum. Stud. 34 , 140–145 (2010).

Kontokosta, C. E. Modeling the energy retrofit decision in commercial office buildings. Energy Build. 131 , 1–20 (2016).

Laskari, M., Karatasou, S. & Santamouris, M. The design of an energy and water advice programme for low-income households. Energy Build. 110 , 426–434 (2016).

Kontokosta, C. E., Reina, V. J. & Bonczak, B. Energy cost burdens for low-income and minority households: evidence from energy benchmarking and audit data in five US cities. J. Am. Plann. Assoc. 86 , 89–105 (2020).

Santamouris, M. et al. On the relation between the energy and social characteristics of the residential sector. Energy Build. 39 , 893–905 (2007).

Bird, S. & Hernandez, S. Policy options for the split incentive: increasing energy efficiency for low-income renters. Energy Policy 48 , 506–514 (2012).

Reina, V. J. & Kontokosta, C. E. Low hanging fruit? Regulations and energy efficiency in subsidized multifamily housing. Energy Policy 106 , 505–513 (2017).

Ramos, A., Gago, A., Labandeira, X. & Linares, P. The role of information for energy efficiency in the residential sector. Energy Econ. 52 , S17–S29 (2015).

Mims, N. et al. Evaluation of US Building Energy Benchmarking and Transparency Programs: Attributes, Impacts, and Best Practices (Lawrence Berkeley National Laboratory, 2017).

Jensen, O. M., Hansen, A. R. & Kragh, J. Market response to the public display of energy performance rating at property sales. Energy Policy 93 , 229–235 (2016).

Fuerst, F. & McAllister, P. Eco-labeling in commercial office markets: do LEED and energy star offices obtain multiple premiums? Ecol. Econ. 70 , 1220–1230 (2011).

Anderson, S. T. & Newell, R. G. Information programs for technology adoption: the case of energy-efficiency audits. Resour. Energy Econ. 26 , 27–50 (2004).

Fleiter, T., Gruber, E., Eichhammer, W. & Worrell, E. The German energy audit program for firms—a cost-effective way to improve energy efficiency? Energy Effic. 5 , 447–469 (2012).

Annunziata, E., Rizzi, F. & Frey, M. Enhancing energy efficiency in public buildings: the role of local energy audit programmes. Energy Policy 69 , 364–373 (2014).

Murphy, L. The influence of energy audits on the energy efficiency investments of private owner-occupied households in the Netherlands. Energy Policy 65 , 398–407 (2014).

Baechler, M.C. A Guide to Energy Audits PNNL-20956 (Pacific Northwest National Laboratory, 2011).

Varone, S. & Varsalona, P. Complying with Local Law 87/09 (Rand Engineering and Architecture, 2018); https://randpc.com/ask/mep/local-law-8709

Estimating Fuel Mix and Energy Cost (Environmental Protection Agency, 2018); https://portfoliomanager.energystar.gov/pdf/reference/FuelMixandCost.pdf

Krutwig, M. C. & Tantău, A. Obligatory versus voluntary energy audits: are there differences in quality?. Proc. Int. Conf. Bus. Excellence 12 , 522–532 (2018).

Shapiro, I. 10 common problems in energy audits. ASHRAE J. 53 , 26–31 (2011).

One City Built to Last (City of New York, 2014); https://www1.nyc.gov/assets/builttolast/downloads/OneCity.pdf

Nair, G., Gustavsson, L. & Mahapatra, K. Factors influencing energy efficiency investments in existing Swedish residential buildings. Energy Policy 38 , 2956–2963 (2010).

Harris, J., Anderson, J. & Shafron, W. Investment in energy efficiency: a survey of Australian firms. Energy Policy 28 , 867–876 (2000).

Marasco, D. E. & Kontokosta, C. E. Applications of machine learning methods to identifying and predicting building retrofit opportunities. Energy Build. 128 , 431–441 (2016).

Papadopoulos, S. & Kontokosta, C. E. Grading buildings on energy performance using city benchmarking data. Appl, Energy 233 , 244–253 (2019).

Energy Star Portfolio Manager: Climate and Weather Technical reference (US Environmental Protection Agency, 2019).

Kontokosta, C. E. & Tull, C. A data-driven predictive model of city-scale energy use in buildings. Appl. Energy 197 , 303–317 (2017).

Efron, B. Bayesians frequentists, and scientists. J. Am. Stat. Assoc. 100 , 1–5 (2005).

MathSciNet   MATH   Google Scholar  

Clark, J. S. Why environmental scientists are becoming Bayesians. Ecol. Lett. 8 , 2–14 (2005).

Murphy, K. P. Machine Learning: a Probabilistic Perspective (MIT press, 2012).

Gelman, A. et al. Bayesian Data Analysis (Chapman and Hall/CRC, 2013).

Hoffman, M. D. & Gelman, A. The No-U-Turn Sampler: adaptively setting path lengths in Hamiltonian Monte Carlo. J. Mach. Learn. Res. 15 , 1593–1623 (2014).

Hyndman, R. J. Computing and graphing highest density regions. Am. Stat. 50 , 120–126 (1996).

Dehejia, R. H. & Wahba, S. Propensity score-matching methods for nonexperimental causal studies. Rev. Econ. Stat. 84 , 151–161 (2002).

Rosenbaum, P. R. & Rubin, D. B. The central role of the propensity score in observational studies for causal effects. Biometrika 70 , 41–55 (1983).

Download references

Acknowledgements

We thank the NYC Mayor’s Office of Sustainability for sharing the LL84 benchmarking and LL87 energy audit data used in this study. We also thank participants at the ‘Next Generation Building Efficiency Policies’ workshop hosted by the NYU Law School and NYU Marron Institute for their feedback on preliminary versions of this work, and K. Hoffman for useful discussions on methodology. The research was supported by National Science Foundation Grant no. 1653773 and by the Sloan Foundation. All errors remain our own.

Author information

Authors and affiliations.

Marron Institute of Urban Management and Center for Urban Science & Progress, New York University, New York, NY, USA

Constantine E. Kontokosta

Guarini Center on Environmental, Energy and Land Use Law, NYU School of Law, New York, NY, USA

Danielle Spiegel-Feld

Department of Civil and Urban Engineering and Center for Urban Science & Progress, New York University, New York, NY, USA

Sokratis Papadopoulos

You can also search for this author in PubMed   Google Scholar

Contributions

All the authors contributed equally to all aspects of the work presented in this article.

Corresponding author

Correspondence to Constantine E. Kontokosta .

Ethics declarations

Competing interests.

The authors declare no competing interests.

Additional information

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Cite this article.

Kontokosta, C.E., Spiegel-Feld, D. & Papadopoulos, S. The impact of mandatory energy audits on building energy use. Nat Energy 5 , 309–316 (2020). https://doi.org/10.1038/s41560-020-0589-6

Download citation

Received : 27 August 2019

Accepted : 26 February 2020

Published : 30 March 2020

Issue Date : April 2020

DOI : https://doi.org/10.1038/s41560-020-0589-6

Share this article

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

This article is cited by

Building energy savings by green roofs and cool roofs in current and future climates.

  • Qingwei Zhong

npj Urban Sustainability (2024)

Application of artificial intelligence in green building concept for energy auditing using drone technology under different environmental conditions

  • Mohd Parvez
  • Subash Thanappan

Scientific Reports (2023)

Promoting energy efficiency at household level: a literature review

  • María del Mar Solà
  • Amaia de Ayala
  • Marta Escapa

Energy Efficiency (2021)

Quick links

  • Explore articles by subject
  • Guide to authors
  • Editorial policies

Sign up for the Nature Briefing: Anthropocene newsletter — what matters in anthropocene research, free to your inbox weekly.

research paper on energy audit

U.S. flag

An official website of the United States government

The .gov means it’s official. Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

The site is secure. The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

  • Publications
  • Account settings

Preview improvements coming to the PMC website in October 2024. Learn More or Try it out now .

  • Advanced Search
  • Journal List
  • Springer Nature - PMC COVID-19 Collection

Logo of phenaturepg

Energy Auditing and Conservation for Educational Buildings: a Case Study on Princess Sumaya University for Technology

Omar mohamed.

Princess Sumaya University for Technology (PSUT), Amman, 11941 Jordan

Saba Fakhoury

Georgina aldalou, ghaliah almasri, associated data.

The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.

This paper introduces shortcut and effective approaches for energy auditing and conservation for educational buildings with application to Princess Sumaya University for Technology. The building electricity is significantly covered by a photovoltaic system, which is included in the building assessments and solutions. The short and simplified computations of the Normalized Performance Indicator of the building have shown fair performance, but some conservation opportunities are still possible. Two feasible energy conservation approaches are presented; the first is by optimization of the operating times of 357 air conditioners in the building using a Genetic Algorithm optimizer. Rigorous effort was done to get an accurate relationship between the comfortable time spans and the average temperatures to ensure the users’ convenience with considering their willingness to exceed the pre-selected optimized time span. Nineteen scenarios over 6 months have attained an average saving of 12.5%, which leads to a payback period of 9.27 years. The second approach is by ThermaCote® building insulation, which attains 38% cost savings with a combined payback period of 19.16 years, including external replacement. Although the existing photovoltaic system supplies a considerable free energy proportion and reduces the billing cost, the proposed two methods have improved the normalized performance indicator from the “fair” range in the existing situation to the “good” range.

Introduction

Background and motivation.

Energy auditing has increasingly become one of the leading services provided by energy companies to the consumers in order to evaluate strategic efficiency improvements and identify considerable energy savings (Yang and Yu 2015 ). Globally, this can be also very useful from many well-known important perspectives: (1) lower cost of consumption for the consumers or the owners of the buildings, (2) cleaner environment due to reduction in emissions of conventional generation, and (3) improved transmission capacities in the grid due to lowered transmitted power to the consumers. One of the main challenges is to have accurate data sets through understanding of the facility; identifying problems of excess energy consumption, if any; and formulating a suitable and logical solution. Energy auditing can be comprehensive, targeted, or preliminary (Beggs 2002 ). Applying direct comprehensive energy auditing can be too detailed, expensive, and time consuming (Kreith and Goswami 2008 ). Preliminary energy audits are crucial in order to identify the essential problems regarding energy consumption in the building energy and suggest practical solutions and this can be usually done without the need to undergo detailed energy audits (Beggs 2002 ). From intensive readings in this field of study, the processes of energy auditing and conservation reports have become deeply understood, which can be summarized as shown in Fig. ​ Fig.1. 1 . This figure shows the simplified or preliminary strategy of auditing using normalized performance indicator (NPI). The NPI is a unified approach for building assessment according to its type (educational, commercial, industrial...etc.). It avoids using the direct numeric value of energy consumption, as similar types of buildings may have different users or occupants, may have different floor areas, or may have different weather conditions. The proposed method of NPI is a unified number range that indicates poor, fair, or good performance of similar types of buildings but having different conditions.

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig1_HTML.jpg

The proposed research methodology

It is better to elaborate on the background of the topic of energy auditing and conservation and their cognitive domains to recognize their multidisciplinary nature and outcomes. Figure ​ Figure2 2 shows the multidisciplinary tendency of the paper topic with emphasis on some useful outcomes of this research and its positive impact on the economy and environment. The research in energy auditing and conservation may be initiated by a center in one engineering discipline with interdisciplinary collaborations with other programs, but the research outcomes and usefulness go beyond the boarders of any one of these disciplines alone.

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig2_HTML.jpg

the multidisciplinary tendency of energy auditing and conservation principles

Students and researchers in the above educational programs should upgrade their knowledge in the overlapping region between those disciplines in order to attain the dual advantage of inexpensive methodology and the corresponding reasonably acceptable results for both energy auditing and energy saving solutions. It is necessary to revise the methodologies published for the aims of building energy auditing and conservation, which are discussed in the next subsection.

Related Work

The variety of some recent published articles on different buildings confirms the interdisciplinary nature of this research area in demanding different disciplines of engineering and artificial intelligence (Veiga et al. 2021 ). The literature has shown variety of auditing methods and energy conservation approaches with emphasis on novel concepts and building characteristics. Al-Saadi ( 2021 ) have diagnosed the building’s operation deficiency via multi-phase energy audits and have suggested pragmatic retrofitting strategies. Rodriguez et al. ( 2021 ) have rather focused on the uncertainty in audit estimations; which has been handled via the Morris method of sensitivity analysis. Al-janabi et al. ( 2019 ) have presented novel information concerning the computational and modeling capabilities of two—widely used—building performance simulators. Osorio et al. ( 2022 ) have presented the direction of research followed by two private higher education institutes in Columbia for carbon neutrality. It has been concluded that higher education institutes not only can contribute to carbon neutrality but also can ensure sufficient cultural awareness of sustainability for their graduates. Nadimuthu and Victor ( 2021 ) have improved the energy efficiency of medicine manufacturing unit via a smart energy management system. Ascione et al. ( 2017 ) have presented retrofitting of energy in educational buildings with application to Italian universities. The energy retrofit measures have taken into account all levers of energy efficiency in buildings, such as building envelops and photovoltaic generation. Multi-objective genetic algorithms have been used as an optimizer to select optimal packages of energy retrofit measures by minimizing thermal energy demand for space heating and coupled with EnergyPlus software for transient building energy simulations. Foroughi et al. ( 2021 ) proposed an optimization model using genetic algorithms (GA), which is coupled with the EnergyPlus software package in order to obtain the optimum window-to-wall ratio (WWR), aspect ratio, and window locations in commercial buildings in the USA. Wang et al. ( 2017 ) have proposed a MILP (mixed integer linear programming)-based approach to schedule a group of interruptible air-conditioning loads in order to relieve the uncertainties of some stochastic variables, such as wind power and ambient temperatures, which eventually improve the wind power utilization and reduce the operational costs. Belany et al. ( 2021 ) have dealt with the possible lighting retrofit and with directed economic analysis for the sake of increasing the energy efficiency of buildings by LED lighting systems. The accuracy of the retrofitted lighting systems has been validated. López-Ochoa et al. ( 2019 ) have explored the possible improvement solutions for some educational buildings in Spain with the aid of some reported Technical Building Codes published by the Spanish Ministry of Development. Twelve proposals have been presented for realizing nearly zero-energy educational buildings. More sophisticated audits are doable by regression and uncertainty analytics, which have shown accurate performance for modeling or prediction of building energy consumption (Mottahedia et al. 2015 ). Conventional regression modeling for building energy estimation has been investigated via three models with data classifications for performance improvements (Ridwana et al. 2020 ). A detailed review of uncertainty analysis in building energy assessment has been published (Tian et al. 2018 ). The review concludes with some possible future directions for a more suitable and rigorous uncertainty analysis of building energy. Lucchi ( 2018 ) has critically reviewed the visualization method that uses infrared thermography as applications of auditing the building energy consumption, where the applications have presented standard and detailed energy audits through detection of excessive heat walls and testing building insulations. Energy audit for a University building has been reported in Leiva et al. ( 2018 ), which has been done by investigating the influences of the individual loads on the total consumption without proposing energy conservation solutions. Lucchi and Delera ( 2020 ) have presented an educational experience of social housing in the San Siro neighborhood in Milan, for refurbishment and improvements of buildings’ sustainability, users’ comfort, and energy efficiencies. The wide range of understandable knowledge of the local situation in terms of the economy and society of that area stimulate the selection of appropriate methods of enhancements. Castrillón-Mendoza et al. ( 2020 ) have described the implementation of a photovoltaic (PV) system at the building of Autónoma of Occidente University by investigating the system outcomes through the building energy consumption post PV installation. It is now clearly realized that the literature has shown a wide-range, cumulative, and appreciated effort that lead to affirmative advancements in the field of building energy auditing and conservation by a combination of simple, multidisciplinary, and complicated methods. However, educational buildings still lack detailed and systematic studies, the scientific contribution of this paper is described in the next subsection. There are common bottlenecks in implementing promising energy auditing methods in educational buildings, such as lack of data, financial barriers, and traditional cultural awareness. However, the proposed method in our paper is as simple as it can be conducted by engineering B.Sc. level of students to evaluate the building performance and suggest potential energy savings, thereby avoiding detailed or expensive energy audits that involve, for instance, computational fluid dynamics (CFD) simulations or infrared thermography extensive accurate diagnosis and assessments.

The Paper Contributions

This paper presents a simplified and validated approach for energy auditing that can be followed by engineers and new graduates of engineering with a thorough understanding of the concept. This proposed preliminary auditing, which is based on NPI, is effective to diagnose the main issues that cause excess energy consumption in the building and it has not been considered in many papers. To the best of the authors’ knowledge and comprehension, it is highly desirable to present a low-cost and direct methodology for energy auditing and conservation for educational buildings with the available data and resources, which eliminates the necessity of having expensive and complex simulation packages to simulate the energy flows, or requires major changes in the building. Therefore, the main novel contributions of this article are:

  • A simple and cost-effective method for energy auditing has been conducted on the building of Princess Sumaya University for Technology. The method is based on calculating the Normalized performance indicators (Beggs 2002 ). The novelty of the contribution is that of the method has been simple enough to be applied by undergraduate engineering students to their University building. This is uncommon in the literature, in which the audits are mostly based on complex energy simulations and expensive software packages that are commonly used by utilities of energy auditing. The NPI computational model of the building has been developed via MATLAB software and Excel formulas that use the monthly electricity bills of 2019 and other relevant data such as the cooling degree days (CDD) and heating degree days (HDD) of the building. It is intended to use the bills of 2019 although other more recent bills are available because that year is the latest year where the building was full of students and their professors before the COVID-19 crises that motivate distance teaching and learning. Overall, the building NPI, with the inclusion of the installed PV system, is found to be within the fair range. Nevertheless, the building still has some remaining opportunities for energy savings. The building per se is still inherently inefficient because it has been just partially supplied by the external free renewable source (The PV system) of energy, but without genuine improvements in the building energy per se, and this motivates the 2nd contribution.
  • Two proposed techniques for energy conservation are suggested based on the analysis of the aforementioned NPI computational model and those energy conservation techniques have made significant improvements in the building energy savings over the existing energy situation of the building. One method is based on using a GA optimizer for optimizing the ACs’ operating hours within the working day time window and grouping the ACs according to their sizes. By studying the financial consequences of the practical implementation of the ACs’ optimizer in the building, it has been found that the system is economically viable with around 9.27 years payback period of the proposed practical control circuitry. The second energy conservation, which saves around 38% of the consumed energy, is by building envelop based on ThermaCote® insulation, with an estimated overall payback period of 19 years, including external replacement. The improvements in the energy consumption have been confirmed by the NPI computation after application of those methods, the NPI has shown that both methods are capable to transfer the NPI from the “fair” range to the “good” range, which indicates genuine improvement in the building energy performance.

The rest of the paper is organized as follows: “Materials and Methods” presents the building description and the required weather data the monthly energy consumption data. “The Building Performance Indication via NPI” presents the NPI calculations, “Proposed Techniques for Improvements in the Building Energy Consumption” illustrates the two proposed techniques for energy savings with their payback periods for practical installation, and finally, “Conclusions” states the conclusions and future recommendations.

Materials and Methods

The case under study is Princess Sumaya University for Technology (PSUT) located at Amman in Jordan, where preliminary energy auditing has been conducted, which is dedicated to the whole building performance assessment. The PSUT building facility is shown in Fig. ​ Fig.3, 3 , which has six main buildings: King Abdullah II School of Engineering, King Hussein School of Computer Science, King Talal School of Business Technology, King Abdullah I School of Graduate Studies and Scientific Research, Deanship of Admission and Registration, Presidency of the University, Deanship of Students’ Affairs, and Al-Hassan Library. Some of these buildings are attached to each other, which gives the possibility of feeding those connected buildings from one meter.

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig3_HTML.jpg

Princess Sumaya University for Technology (PSUT)

The electrical energy bills for the year 2019 have been provided by the Financial Department at the University. The monthly bills for the fuel and electricity have been intentionally adopted for building assessment because they clarify the most recent informative data before the COVID-19 crises, which led to online teaching and learning in 2020 and 2021 and no significant energy consumption in the PSUT building. Because some of these buildings are physically connected, the total number of meters in the building is only four, which supply the whole University campus with electrical energy. Two of the total meters are connected to the PV system as energy supplied to the grid was present in some of their bills. The university has been thus treated as one facility as some individual meters cover more than one building. The analysis requires the energy consumed from the grid as it reflects the loads; therefore, summation of this energy from the four meters data was done for each month as shown in Table ​ Table1 1 .

Energy consumed—from grid

Energy auditing requires studying the total consumption of the building. Consequently, the energy produced by the PV system is needed in order to know the actual electrical energy consumption of the building which reflects the actual loads. The data set for PV energy contributions has been provided and is shown in Table ​ Table2 2 .

PV system generation data

The NPI is calculated by the net energy consumed by the building from the grid and the total gross one, which is consumed by the building that includes the PV. Thereby, the calculated NPIs in both cases altogether have avoided a likely misleading picture for building performance and diagnosis if only one of them is considered. As a result, the field can be opened for many alternative methods for inherent improvements of the building towards lower net energy consumption rather than just supplying partially with PV or other renewable resources, which has no ingrained effect on the building consumption. The total electrical energy consumed can be calculated using the energy produced by the PV system and the electrical energy bills simply as follows:

  • Find the sum of the energy consumed from the grid (kWh) from the provided bills.
  • Find the sum of the energy delivered to the grid (kWh) from the provided bills.

The steps described above have been done for all months. It is specified on the bills that the tariff for the university is “Governmental”, this corresponds to the Regular Subscribers Tariff, which is an increasing block tariff as shown in Table ​ Table3 3 .

Tariff structure

Another approach to find the tariff is by using the billed energy consumption and the total cost to take all costs into account, from the bills available, as follows:

The tariff using this equation has been calculated. Then, the cost of the billed energy has been calculated using both tariffs; the factor and table, to check which one is more consistent with the cost on the bills since the cost may be affected by a certain block more than the other. The most accurate tariff is chosen for the study. The energy from all sources should be considered; therefore, the fuel energy is essential for the study. Five fuel bills were provided that show the fuel consumption in liters and equivalent cost. This data is shown in Table ​ Table4. 4 . According to reference Kolb and Siegemund ( 2017 ), 1 L of diesel fuel contains 10 kWh of energy. Therefore, the energy consumption of the fuel was calculated as follows:

The fuel bills

The building energy data has been summarized as two pie charts in Fig. ​ Fig.4a 4a and ​ andb b .

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig4_HTML.jpg

Data pie chart summary. a Grid vs. PV. b Electricity vs. diesel fuel

Unfortunately, the detailed equipment utilization is not provided for technical reasons; however, it is not quite necessary for NPI calculation and/or suggesting new energy-saving techniques. The equipment utilization is requested in case of detailed and comprehensive energy audits, which is intended in our study. In our study, it has intended to use simplified auditing techniques to prove the ability of engineering students to conduct such audits without expensive or complicated computations and provision of enormous data.

The Building Performance Indication via NPI

This is the analysis technique used to evaluate the energy consumption of the university. Based on the book followed in Beggs ( 2002 ), if the building is air-conditioned, then the energy consumed for space cooling should be calculated, corrected, and then used to find the NPI of the building. However, in this study, the energy consumed for space heating has been also calculated and corrected to achieve more accurate results since it is estimated to be approximately 32.5% of the total energy consumed, that is, the diesel fuel energy over the total energy. The building efficiency is assessed in the following subsection.

NPI Calculations

The process of calculating the NPI is clarified through the work-flow diagram shown in Fig. ​ Fig.5, 5 , where step 1 is for the Corrected space cooling energy consumption, step 2 is for Corrected space heating energy consumption, step 3 is for the Corrected total energy consumption, and finally step 4 is for calculating the NPI. The NPI method is detailed in the text (Beggs 2002 ).

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig5_HTML.jpg

Workflow diagram for NPI calculations

NPI Input Data

The data inputs needed for the NPI calculation are the total energy consumed, degree-day data, the total AC energy consumed, the hours of use in the building, the exposure coefficient, and the total floor area. These requirements are briefly explained in the following subsections.

The Total Energy Consumed in the Building

It is calculated using the electrical energy from the bills and PV system as already explained, and the energy from the fuel. Both energy sources are expressed in the same unit, kWh. The energy of the fuel is multiplied by 0.75 since this is the proportion of the fuel used for space heating (Beggs 2002 ).

Degree days

The cooling and heating degree days, CDD and HDD, respectively, are needed to find the standard and actual CDD and HDD to calculate the weather coefficients.

Standard CDD and HDD

The average CDD and HDD have been downloaded from the widely used website reference (BizEE website 2022 ) for the base temperature 18 °C. The average is based on the past 5 years; 2016–2020 with an average uncertainty of 0.208% for both CDD and HDD. This average is used as the standard CDD and HDD of the building.

Actual CDD and HDD

The daily CDD and HDD for the year 2019 were also downloaded from the same widely used reference (BizEE website 2022 ), for the same base temperature of 18 °C, and have an average uncertainty of 0.0657%. Then, the CDD and HDD of the weekends, Fridays and Saturdays, and the holidays based on PSUT’s academic calendar for the year 2019 have been excluded in calculating the actual CDD and HDD for the building.

This data was downloaded from the station Amman Airport, JO (35.99E, 31.97N) since it was the closest to PSUT’s location which is (35.88E, 32.02N). The base was chosen to be 18 °C for two reasons:

  • The work reported in (Almuhtady et al. 2019 ) explains that this base is usually used for the past 30 years based on Jordan’s climate.
  • According to the American Society of Heating, Refrigerating and Air-Conditioning Engineers ASHRAE 55, the indoor comfort temperature is around 22 or 23 °C, which is consistent with the chosen base taking the indoor heat sources and Jordan’s climate into consideration, refer to the reference (ASHRAE. 2017 ).

To ensure logical results, the CDD data was also downloaded for base temperatures 15.5 °C and 20 °C, which gave much higher and lower values compared with base 18 °C, respectively.

Total air conditioner AC energy consumed

Air conditioner ac data.

The sizes of the air conditioners present in PSUT along with the number of each size were provided as shown in Table ​ Table5. 5 . It shows that the total AC power for PSUT 578.5 kW.

AC data provided. Rule of thumb: 1 ton consumes 1 kW

AC energy consumed for cooling and heating

The total AC energy consumed can be estimated by either assuming a percentage of the total energy based on a study already done on a similar building with a similar climate, or by calculating an approximate based on relevant data. The second approach was done as follows: Using the daily actual degree days DD data, the number of days per month for which the DD is more than 1.5 was calculated in order to exclude days with DD of 0.1. Then, the sum of CDD days for each month was found to know how many days cooling is needed each month. Similarly, the HDD days per month were found. The number of operating hours of ACs is influenced by many factors, such as weather temperature, users’ willingness, and comfort. However, the total operational hours can be reasonably assumed to be linked with either the CDD or a forecasted dry-bulb temperature in order to optimally decide the most economical operating hours for each size of the ACs.

The number of hours per day for which the AC is on for both cooling and heating was assumed with the best reasoning known.

The total power of all AC sizes has been calculated; assuming 1 kW/1 ton is drawn as a rule of thumb. Therefore, using these 3 parameters, the consumption was calculated through Eqs. ( 17 )–( 18 ):

Since we are dealing with an educational building, it can be reasonable to estimate ACs operating hours per working day. The assumptions are mentioned in Table ​ Table6 6 .

AC hours/day assumptions

Hours of Use

The standard hours of use per year are 4250 (Beggs 2002 ) to be able to compare the NPI with the yardsticks. The actual hours of use per year were calculated by assuming 8 working hours per day, excluding the weekends; Fridays and Saturdays, and the holidays based on PSUT’s academic calendar of 2019. Similarly, the days of use have been calculated.

The area of each floor for all buildings of PSUT was provided. The net internal area for each floor for all buildings has been added to find the total floor area of the building, which is needed for the NPI. The average area for each building was found by finding the average of all floors for each building. Then, the total ground area by finding the summation of the average area for all buildings. Also, the total floor area is approximately found using the following relation:

NPI Results

The NPI has been calculated for different cases in order to find the most logical and accurate result. Figures ​ Figures6 6 and ​ and7 7 show the input and output as depicted from the developed NPI excel calculator sheet, respectively.

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig6_HTML.jpg

Inputs of NPI calculator

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig7_HTML.jpg

Outputs of NPI calculator

Proposed Techniques for Improvements in the Building Energy Consumption

In this section, the energy conservation methods for building consumption improvements are introduced. Although the building energy is largely covered by the PV system, especially in the summer season, it has been found that the building is inherently still not efficient and some energy conservation strategies must be applied to reduce its gross energy consumption. The PV system acts like an external free source and has no ingrained effect on the building consumption. To avoid any possible misleading pictures on the building efficiency, two energy conservation principles have been proposed, one is based on GA to optimally schedule the operating time span for all air conditioners according to the forecasted temperature or the predicted CDD from historical data. The reason for selecting air conditioners’ circuit rather than lighting or computer can be justified through basic inspection of the rating of the devices in the building, which obviously has shown that the air conditioners are the highest energy-consuming devices in the building. The time windows of operation for each size-grouped air conditioners are decided in advance with free desire of the users to switch on/off. The assumptions have included many operating optimal scenarios produced by GA that have been compared with other hypothetical scenarios with average cost savings of around 12.5 % of the total cost per year with 9.27 years payback period. The second method is by proposing a building envelop of ThermaCote® that attains further 38% cost savings per year with a combined payback period of 19.16 years. It is noticed that the latter can be relatively longer to recover; however, this payback period is combined after the applications of the PV system and the GA air-conditioning optimizer, and even so, it can be comparable to other buildings with other energy investment projects for other buildings (Zhang et al. 2021 ). Overall, this is certainly useful environmentally and economically with reasonably acceptable payback periods for educational buildings due to their sustainability for several decades to come. The next subsections describe the proposed energy conservation with their investment analysis.

The Genetic Algorithm Optimizer

Genetic Algorithm is a well-known meta-heuristic optimization technique that represents a class of artificial intelligence. Because it was inspired by the Darwinian theorem, it follows the mechanism of natural selection, but in a mathematical and iterative fashion. The surviving parameters produce the best fit which evolves towards the global optimal solution by three main actions: reproduction, crossover, and mutation, which are applied in each generation of parameters. Every action has specific settings in order to obtain—or accelerate—the solution. It has been shown that GA is a rigorous optimization technique that is capable of resolving many highly complex and practical optimization problems, such as parameter identification of coal mills (Guo et al. 2014 ) and modeling energy-efficient supercritical power plants (Mohamed et al. 2011 ). The simplified schematic for GA is shown in Fig. ​ Fig.8. 8 . The idea is mathematically based on the fact that there are infinitely set of operating hours of the AC groups that could satisfy the consumers, according to the daily expected average temperature, with different costs of consumption; nevertheless, there is an optimal choice among all these sets that make the cost minimum which corresponds to minimum energy consumption.

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig8_HTML.jpg

GA flow diagram

The objective function to be minimized for a unified size group of ACs is assumed to be a quadratic cost function and the optimization problem can be mathematically described through Eqs. ( 7 )–( 10 )

Subject to the following equality and inequality constraints

where H i is the scheduled operating hours for a group of ACs that have the same size; these scheduled hours are to be optimally found by GA to minimize the total cost C i of electricity. The coefficients α i ,  β i , and γ i are simply determined by a curve fitting tool either in MATLAB or Microsoft excel. The curves are built by the relationship of the CDD or average temperature with the operating hours of a group of ACs. H total has been considered equality constraint, which is the summation of total operating hours for the groups of ACs pre-determined either by the forecasted average temperature or the CDD on a working day. It can be alternatively represented by the operating hours of the ACs in the offices, the classrooms, and the stadiums. The inequality constraints are adjusted to fit the working day hours to allow maximum flexibility for the AC user. After using determining the coefficients of the cost function of each group, they have been recognized by the GA optimizer as an M-File representing the objective function. Many scenarios were tested; nonetheless, the most satisfactory results are obtained with population-type double vector, population size of 50, heuristic crossover, Gaussian mutation function, and mutation rate of 0.1.

Sizes, Quantities, and Rooms of Air conditioners

In the data collection phase of the audit, it has been given that there are 4 AC sizes, distributed in 4 types of rooms as in Table ​ Table7 7 .

Air conditioner data for PSUT

The power of each size is calculated using Eq. ( 11 ), assuming that (1 ton = 1kW):

The Bounds of Operating Hours and Practical Correlations

In order to optimize the system, the number of operating hours for each size of the 4 AC sizes must be bounded. The bounding criterion is decided according to the daily average temperature in summer, in which the maximum daily average temperature corresponds to the full working-day hours and the minimum average temperature corresponds to the minimum hours, which are selected to be two hours for the offices and classrooms. The number of operating hours boundaries for each room type have been assumed logically depending on the occupancy trends for each room type in PSUT, two cases were studied as follows:

  • The first case was that all air conditioner sizes had the same lower and upper bounds which are 2–7 h/day.
  • The second case was to keep the first 3 sizes with the same 2–7 h/day boundary and reduce the boundary of the 4th size to 0–3 h/day.

The lower and upper bounds are assumed according to the most guessed users’ activity during the daily working hours of the building. The credit hours of the largest air conditioners are actually low even on the hottest days because they are installed in auditoriums and corridors where the occupancy rate is very low, especially the auditoriums where the activities are only the invited talks and non-scheduled lectures that may happen once every week throughout the academic year. In addition, the two assumed cases have been extensively tested for many simulation scenarios for the proposed automatic energy conservation via GA and the results were more consistent when applying the constraints in case 2. It also is important to mention that, the automation of the proposed design of the practical control system, which is described in the next subsection, allows flexibility of the user to exceed the time span decided by the GA optimizer if needed or even switch off the AC, but the GA optimizer controls the ACs operation hours instructively and automatically. Therefore, the savings can be economically viable as average cost savings after many days of operation of this optimal strategy in comparison to other hypothetical cases on the same number of days where the GA optimizer and the proposed smart system do not work.

A curve fitting tool has been used to develop the cost equations for each AC size so we have four quadratic cost equations representing the time-span of the operating hours of each grouped size. The daily data of the cooling degree days of Amman between May and October is obtained. Considering 18 °C as the base temperature; the maximum and minimum CDD are assigned to the maximum and minimum number of operating hours assumed for PSUT which are equal to 24 and 6 hr./day, respectively. The 0 h/day is assigned to the base temperature, i.e., where no cooling is needed. It is logical to relate the daily operating hours to the forecasted daily average temperature using historical data, which was calculated using the CDD as follows:

Note that the minimum CDD is 1.5 DD even if smaller CDD are available because this is the minimum CDD value to consider cooling on that day. The next subsection shows the practical automation system, cost savings associated with GA, and the payback period.

The Proposed Practical GA Optimizer

The Genetic Algorithm method is a proposed energy conservation system that needs a reasonably acceptable budget to implement. The practical implementation of the Genetic Algorithm method of optimizing the number of daily operating hours for each size of the air-conditioning system is done using a smart system which is responsible for all the air conditioners in PSUT. This computerized smart system should be connected to all the air conditioner switches in the facility. Figure ​ Figure9 9 depicts the proposed practical automation system for more economical operation of the ACs. In order to do this, the following components are needed:

  • Centralized smart computer (1 item).
  • Thermostats—one for each air conditioner (357 items).
  • Timer switches—one for each air conditioner (357 items).
  • D/A converters or Arduino—one for each air conditioner group with the same size (4 items).

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig9_HTML.jpg

Practical foresight for the proposed optimizer or control strategy

To implement this system, specialists in the field of smart systems are needed. Also, a long time and a budget are needed in order to purchase these components. As mentioned earlier in the abstract, in some cases, the user’s remote control may bypass this automation circuitry to switch ON/OFF the AC in his/her room; however, such cases are not dominant, and therefore, they have trivial effects on the overall intelligent decision for this large number of ACs because of the following reasons:

  • The operating hours are decided overall by the GA optimizer for the large number of ACs within boundaries of practical time spans that are rooted in the average temperature and the CDD; therefore, any slight mismatches result in near-optimal decisions, which is also economical. If the mismatch is due to switching off, then that can be more optimal, if it is due to exceeding some few time spans, then it is a near-optimal decision.
  • The proposed controller has been designed and tested in the worst cases, in which all ACs are turned ON and compared against many hypothetical cases with considerable average cost savings. Therefore, the success of this strategy is clarified by the fact that the cost savings are calculated over many days of operation, not necessarily per-day cost saving.

In the suggested design, 357 timer switches are used, one for each AC, or an advanced multiple-device programmable timer switches may be used, with less number of required items. The time span for each grouped size ACs is calculated as follows

It is also expected that the practical installation should reveal some needs for calibrations either on the data inputs or the scheduling limits; however, the overall investment, cost savings, apparatus used, and payback period is comparable with the calculated one in the next subsection.

The Controller Economic Analysis

An economic analysis is done to ensure the feasibility of the proposed control system. Table ​ Table8 8 summarizes the components needed, quantity of each component, and estimated prices. The prices are estimated by surfing many national and international websites for marketing embedded systems, but the prices are mentioned in JOD. This strategy of ACs control is designed for cooling purposes. Thus, the assumption for the air-conditioning usage period is from May to October. Many hypothetical assumptions have been assumed (Table ​ (Table9 9 ).

The control system components, quantity for each component, and price

Savings percentage in comparison to other hypothetical cases

These hypothetical cases are calculated to take advantage of the average cost savings, in order to compare with the optimal near-optimal decisions of the GA controller and it is not recommended to mention the details of all of them here; however, one sample achieved saving in someday is mentioned in Table ​ Table10 10 .

Economic analysis summary of assumption 9

The GA method resulted in 12.5% average savings if used in PSUT which are obtained theoretically as shown in Tables ​ Tables9 9 and ​ and8; 8 ; 19 assumptions of different total operating hours have been studied to calculate the most realistic average savings of the GA tool which appears to be 12.5%. The two extreme cases which are the minimum and maximum operating hours which result in 0 savings were taken into consideration when calculating the average savings. The total energy costs before implementing the GA and after the GA with the corresponding savings in JOD are mentioned in Table ​ Table11 11 .

Total cost and saved cost

Thus, the payback period is calculated using the investment cost and saved cost as follows:

To conclude the analysis, the results above ensure that implementing this control system is feasible and beneficial for PSUT as it returns its initial cost approximately 9.3 years after the installation, which is acceptable for an educational building. This is the worst payback period due to the largest number of components used; it may range from 5 to 9 years if other approaches are chosen.

Improvement Reflected on the NPI

The NPI has been improved since the GA results in 12.5% decrease in energy used for cooling. It was calculated as already explained, but with the following changes since the reduction is only in the cooling energy:

The NPI is reduced to 3.59% and is equal to 339.82 kWh/m 2 , which is still in the “fair” range. This is shown in Figs. ​ Figs.10 10 and ​ and11 11 .

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig10_HTML.jpg

NPI inputs—post GA

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig11_HTML.jpg

NPI outputs—post GA

The Building Insulation Method

Proper building insulation reduces both the energy and NPI by 38% according to the product data sheet and presentations of ThermaCote® (ThermaCote® website 2022 ). Thermacote® Insulation of buildings is a high-performance paint ceramic heat-resistant material that leads to significant energy savings for the building (ThermaCote® website  2022 ). Hence the actual NPI reaches the “good” range for either case of total energy consumed by the building or excluding the energy shared by the PV system, as shown in Table ​ Table12 12 and Fig. ​ Fig.12. 12 . It has saved 301141.16 kWh for the assumed case.

Insulation energy reductions

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig12_HTML.jpg

Improvements before and after insulation

Economic Analysis Results of the Proposed Energy Conservation Methods

The results of the economic analysis are shown in Table ​ Table13 13 .

Insulation economic analysis

It is stated that the ThermaCote® product is guaranteed for life for indoor applications, and 10 years for outdoor use (ThermaCote® website  2022 ). If the total energy is considered, case 1, the payback is 2.89 years which implies the recommendation is feasible. However, this is not the actual cost since the energy covered by the PV system is for free now, so this only means that if the insulation was improved before installing the PV system it would have been feasible.

Two scenarios were studied where only the energy from the grid is considered:

  • Using the same investment cost and this gives a payback period of 12.89 years. It is greater than 10 years; however, the insulation is internal and external, so it can be considered feasible. However, to ensure that, maintenance of the external coating should be considered for a longer lifetime.
  • Using the following investment cost:

That is, the investment cost is 50% higher when assuming the external insulation is replaced which accounts for the worst case of maintenance. This case has shown a lifetime of 20 years, so a payback of 19.33 years is feasible and saves 26451.18 JOD annually. The cost-saving opportunities due to the load shifting concept may exist if the tariff depends on the time, peak, night, or day, or if a penalty on the maximum demand exists. However, this is not applicable for this study since the tariff structure is the Regular Subscribers’ tariff which is an increasing block tariff. Consequently, there are no cost-saving opportunities depending on this concept.

Summary of Combined Improvements

The cost reductions for the GA control and insulation improvements are summarized in Table ​ Table14, 14 , along with the reduction caused by installing both recommendations.

Improvement summary over one year of typical actual energy consumption of 2019

The payback period if both improvements are done together can also be calculated using Table ​ Table14 14 as follows:

The NPI calculation of both improvements is depicted in Figs. ​ Figs.13 13 and ​ and14 14 from the NPI excel calculator.

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig13_HTML.jpg

The inputs to the combined improved NPI computing

An external file that holds a picture, illustration, etc.
Object name is 41660_2022_273_Fig14_HTML.jpg

The combined Improvements as reflected in NPI

Finally, the calculated payback period for the building insulation could be too long for residential customers. However, It can be accepted by most educational buildings and there are similar payback periods in the literature for other solutions and other types of buildings. One may argue that this is too long to be accepted by most residential customers, but in fact, it is very suitable and economically viable for educational buildings where the building is very likely to be with the same owner(s) for many coming decades. The return cycle could be much lower if the PV contribution is not considered; however, it is intended to include the PV contribution as free energy and consider the cost of electricity from the grid, which results in this payback period. As might be a subject of interest to some researchers, the reduction in carbon emission from the contribution of the solar PV system may be mentioned. From the website (Boston Solar Website 2022 ) as a typical generalized example of the basic calculation, 1 kWh electricity from solar is equivalent to 0.846 lbs reduction in CO 2 emission or 0.383 kg. By referring to Table ​ Table2, 2 , 957123.26 kWh is the total annual PV generation from the data of 2019, the year just before the corona crises, which is equivalent to a carbon reduction of 366578.2 kg.

Conclusions

In this paper, a simplified energy audit has been conducted on the PSUT building, which has targeted the whole building consumption with suggested improvements to the AC system.

The following points present the concluding remarks and findings from the data and results:

  • The energy consumed by the PSUT building has been partially covered by a PV system since 2016.
  • Energy audits of the building have been conducted via the NPI method, with monthly energy bills of 2019, including the share of the PV system, with the result of fair building performance.
  • The reason for choosing the 2019 bills is that it is the last year where it was full of students, professors, and employees, before the COVID-19 crisis that stimulates online classes with no significant energy consumption.
  • Although the NPI has shown fair-range performance, two proposed energy conservation methods are proposed, one on optimizing the ACs’ operation times by GA, and the other by building insulation with high-performance ceramic material manufactured by Thermacote.
  • The relevant payback periods are calculated and discussed for guaranteed and economically viable performance.
  • These approaches have successfully reduced the cost and energy by 12.5 % in the summer and the NPI by 3.59 % in comparison to hypothetical and actual cases. In addition, building insulation developed by a recognized company has been suggested, which has resulted in 38% savings and energy, NPI, and total cost. Both methods cause approximately 40% savings.
  • The proposed methods have driven the NPI from the “fair” range to the “good” range according to international standards.

The proposed methods have been evaluated based on the real data of the Jordan climate and the accurate energy consumption of the building, which considers the data of gas and power consumption in addition to the PV power share. This method is much simpler than other detailed energy audits and solutions and comparable in accuracies and outcomes. Other characteristics are best assumed from our experience of the building and search skills, such as the constraints imposed on the working hours of the ACs and the estimated prices for the appliances of the control strategy of ACs. However, every study needs some potential data besides some sort of logical assumptions so that the study can be realized.

Future recommendations can be stated as follows: The Genetic Algorithm method can be extended for heating purposes during winter alongside the current usage of cooling purposes controlling the operating hours using different codes of GA to account for HDD instead of CDD. This eventually results in further billing cuts. The paper has included the full data and information so that it can be additionally regarded as an educational guide to other future researchers worldwide to conduct such simplified audits, subject to data availability in the building facility or facilities they aim to improve. Further explanations could be published as a critical review article to discuss, for instance, how the proposed NPI method is simple and to what extent other methods are expensive and complicated. The implication of more accurate consumption of the ACs seems to be possible by smart energy meters. Despite the satisfactory performance of the GA optimizer, swarm optimizers may have faster capability for producing the solutions. More walk-through audits could be made to test the building via infrared thermography and thermal examination of the building’s proposed insulator if it is approved and installed. LED lighting replacement with a recent lighting system is another possible future feasibility study. Sophisticated studies can be also suggested to account for emission reduction from building insulation and smart control of air conditioners. Finally, since the PV system covers the highest proportion of energy of 78% of the building consumption, the solar PV system may need extensive studies to be conducted as optimization problems, such as maximum power point tracking (MPPT) and/or Operating and Maintenance Standard Operating Procedures (O&M SOPs). However, the last point requires enormous data and significant amount of research work.

Abbreviations

Data availability, declarations.

The authors declare no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Omar Mohamed, Email: [email protected] .

Saba Fakhoury, Email: moc.liamg@yruohkafaabas .

Georgina Aldalou, Email: [email protected] .

Ghaliah Almasri, Email: moc.liamg@irsamlahailahg .

  • Al-janabi A, Kavgic M, Mohammadzadeh A, Azzouz A. Comparison of energyPlus and IES to model a complex university building using three scenarios: free-floating, ideal air load system, and detailed. J Build Eng. 2019; 22 (2019):262–280. doi: 10.1016/j.jobe.2018.12.022. [ CrossRef ] [ Google Scholar ]
  • Almuhtady A, Alshwawra A, Alfaouri M, Al-Kouz W, Al-Hinti I. Investigation of the trends of electricity demands in Jordan and its susceptibility to the ambient air temperature towards sustainable electricity generation. Energy, Sustain Soc. 2019; 9 (1):39. doi: 10.1186/s13705-019-0224-1. [ CrossRef ] [ Google Scholar ]
  • Al-Saadi SN. Pragmatic retrofitting strategies for improving thermal, energy, and economic performance of an institutional building in a cooling-dominated climate. J Build Eng. 2021; 44 :103326. doi: 10.1016/j.jobe.2021.103326. [ CrossRef ] [ Google Scholar ]
  • American Society of Heating, Refrigerating, and Air-Conditioning Engineers [ASHRAE] ANSI/ASHRAE Standard 55-2017: Thermal environmental conditions for human occupancy. Atlanta: American Society of Heating, Refrigerating, and Air-Conditioning Engineers; 2017. [ Google Scholar ]
  • Ascione F, Bianco N, De Masi RF, Mauro GM, Vanoli GP. Energy retrofit of educational buildings: transient energy simulations, model calibration and multi-objective optimization towards nearly zero energy performance. Energy Build. 2017; 144 :303–319. doi: 10.1016/j.enbuild.2017.03.056. [ CrossRef ] [ Google Scholar ]
  • Beggs C. Energy management and conservation . Amsterdam: Elsevier Ltd; 2002. [ Google Scholar ]
  • Belany P, Hrabovsky P, Kolkova Z. Combination of lighting retrofit and life cycle cost analysis for energy efficiency improvement in buildings. Energy Rep. 2021; 7 :2470–2483. doi: 10.1016/j.egyr.2021.04.044. [ CrossRef ] [ Google Scholar ]
  • BizEE Degree Days Weather Data for Energy Saving (2022) Available at https://www.degreedays.net/ . Accessed August 2022
  • Boston Solar Website: How Much CO2 Do Solar Panels Save? (2022) Available at: https://www.bostonsolar.us/solar-blog-resource-center/blog/how-much-co2-do-solar-panels-save/ . Accessed July 2022
  • Castrillón-Mendoza R, Manrique-Castillo PA, Rey-Hernández JM, Rey-Martínez FJ, González-Palomino G (2020) PV Energy Performance in a Sustainable Campus. Electronics 9(11):1874. 10.3390/electronics9111874
  • Foroughi R, Asadi S, Khazaeli S. On the optimization of energy efficient fenestration for small commercial buildings in the United States. J Clean Prod. 2021; 283 :124604. doi: 10.1016/j.jclepro.2020.124604. [ CrossRef ] [ Google Scholar ]
  • Guo S, Wang J, Wei J, Zachariades P. A new model-based approach for power plant tube-ball mill condition monitoring and fault detection. Energy Convers Manag. 2014; 80 :10–19. doi: 10.1016/j.enconman.2013.12.046. [ CrossRef ] [ Google Scholar ]
  • Kolb O, Siegemund S. For DENA- German energy agency: final report- study on the implementation of article 7(3) of the “directive on the deployment of alternative fuels infrastructure” –fuel price comparison. Brussels: European Commission, Directorate General for Mobility and Transport; 2017. [ Google Scholar ]
  • Kreith F, Goswami Y. Energy management and conservation handbook . Boca Raton: CRC Press; 2008. [ Google Scholar ]
  • Leiva E, Villacreses S, Benítez DS. In 2018 IEEE ANDESCON . Santiago de Cali: IEEE; 2018. Electrical energy audit of university buildings: Case study at Universidad San Francisco de Quito; pp. 1–6. [ Google Scholar ]
  • López-Ochoa LM, Bobadilla-Martínez D, Las-Heras-Casas J, López-González LM. Towards nearly zero-energy educational buildings with the implementation of the Energy Performance of Buildings Directive via energy rehabilitation in cold Mediterranean zones: The case of Spain. Energy Rep. 2019; 5 :1488–1508. doi: 10.1016/j.egyr.2019.10.008. [ CrossRef ] [ Google Scholar ]
  • Lucchi E. Applications of the infrared thermography in the energy audit of buildings: a review. Renew Sust Energ Rev. 2018; 82 :3077–3090. doi: 10.1016/j.rser.2017.10.031. [ CrossRef ] [ Google Scholar ]
  • Lucchi E, Delera AC. Enhancing the historic public social housing through a user-centered design-driven approach. Buildings. 2020; 10 :159. doi: 10.3390/buildings10090159. [ CrossRef ] [ Google Scholar ]
  • Mohamed O, Wang J, Guo S, Al-Duri B. Mathematical modeling of coal fired supercritical power plant and model parameter identification using genetic algorithms. In: Ao SI, Gelman L, editors. In Electrical Engineering and Applied Computing. Lecture Notes in Electrical Engineering . 90. Berlin: Springer; 2011. [ Google Scholar ]
  • Mottahedia M, Mohammadpour A, Amirib SS, Rileyb D, Asadib S. Multi-linear regression models to predict the annual energy consumption of an office building with different shapes. Procedia Eng. 2015; 118 :622–629. doi: 10.1016/j.proeng.2015.08.495. [ CrossRef ] [ Google Scholar ]
  • Nadimuthu LPR, Victor K. Optimization of energy-intensive process in ayurvedic medicine manufacturing unit—a case study. Process Integr Optim Sustain. 2021; 5 :975–992. doi: 10.1007/s41660-021-00194-3. [ CrossRef ] [ Google Scholar ]
  • Osorio AM, Úsuga LF, Vásquez RE, Nieto-Londoño C, Rinaudo ME, Martínez JA, Filho WL. Towards Carbon Neutrality in Higher Education Institutions: Case of Two Private Universities in Colombia. Sustainability. 2022; 14 (3):1774. doi: 10.3390/su14031774. [ CrossRef ] [ Google Scholar ]
  • Ridwana I, Nassif N, Choi W. Modeling of building energy consumption by integrating regression analysis and artificial neural network with data classification. Buildings [online] 2020; 10 (11):198. doi: 10.3390/buildings10110198. [ CrossRef ] [ Google Scholar ]
  • Rodriguez A, Smith ST, Potter B. Sensitivity analysis for building energy audit calculation methods: handling the uncertainties in small power load estimation. Energy. 2021; 238 :121511. doi: 10.1016/j.energy.2021.121511. [ CrossRef ] [ Google Scholar ]
  • Thermacote® Website (2022) Available at: https://thermacote.com/ . Accessed August 2022
  • Tian W, Heo Y, De Wilde P, Li Z, Yan D, Park CS, Feng X, Augenbroe G. A review of uncertainty analysis in building energy assessment. Renew Sust Energ Rev. 2018; 93 :285–301. doi: 10.1016/j.rser.2018.05.029. [ CrossRef ] [ Google Scholar ]
  • Veiga RK, Veloso AC, Melo AP, Lamberts R. Application of machine learning to estimate building energy use intensities. Energy Build. 2021; 249 :111219. doi: 10.1016/j.enbuild.2021.111219. [ CrossRef ] [ Google Scholar ]
  • Wang D, Meng K, Gao X, Coates C, Dong Z. Optimal air-conditioning load control in distribution network with intermittent renewables. J Mod Power Syst Clean Energy. 2017; 5 :55–65. doi: 10.1007/s40565-016-0254-z. [ CrossRef ] [ Google Scholar ]
  • Yang M, Yu X. Energy efficiency: benefits for environment and society. London: Springer; 2015. pp. 11–42. [ Google Scholar ]
  • Zhang C, Hu M, Laclau B, Garnesson T, Yang X, Tukker A. Energy-carbon-investment payback analysis of prefabricated envelope-cladding system for building energy renovation: Cases in Spain, the Netherlands, and Sweden. Renew Sust Energ Rev. 2021; 145 :111077. doi: 10.1016/j.rser.2021.111077. [ CrossRef ] [ Google Scholar ]

Energy Audit: A Case Study

Ieee account.

  • Change Username/Password
  • Update Address

Purchase Details

  • Payment Options
  • Order History
  • View Purchased Documents

Profile Information

  • Communications Preferences
  • Profession and Education
  • Technical Interests
  • US & Canada: +1 800 678 4333
  • Worldwide: +1 732 981 0060
  • Contact & Support
  • About IEEE Xplore
  • Accessibility
  • Terms of Use
  • Nondiscrimination Policy
  • Privacy & Opting Out of Cookies

A not-for-profit organization, IEEE is the world's largest technical professional organization dedicated to advancing technology for the benefit of humanity. © Copyright 2024 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.

Energy Audit in an Indian University—A Case Study

  • Conference paper
  • First Online: 21 April 2021
  • Cite this conference paper

research paper on energy audit

  • Hamad Khan 39 ,
  • Akif Siddiqui 39 ,
  • Aqeel Ahmad Ansari 39 &
  • Nidal Rafiuddin 39  

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 723))

535 Accesses

With the 1973 oil crisis and environmental concerns because of burning of fossil fuels and further with the limitations in available energy resources, it has become imperative to harness environmentally friendly non-conventional energy sources and manage energy consumption judiciously. The present work focusses on effective energy management from an audit performed on hall of residences of an Indian university namely Aligarh Muslim University by replacing major inefficient loads by efficient loads and estimates solar energy that can be harnessed. There are about nineteen student residences in Aligarh Muslim University. To ensure maximum electrical energy efficiency and cost saving, while energy auditing on one hall namely Nadeem Tareen was conducted, it was estimated on all other halls of residence. Firstly, all major loads in the hall of residence were identified and their power consumption and quality were measured using appropriate tools. The GridVis 7.2 software was used for this purpose. The major loads are the primary audit concerns as they possess the highest potential for energy saving. Replacing existing lighting and fans with LED bulbs and BLDC fans, respectively, were entertained as conservation opportunities and consequent costs calculated. The rooftop areas of all of the remaining hostels were measured using Google Maps tool, further solar plant capacity was calculated. If the proposed changes are implemented on all hall of residences, an estimated INR 6.3 crore can be saved annually.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
  • Available as EPUB and PDF
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
  • Durable hardcover edition

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Turner WC, Doty S (2007) Energy management handbook, 6th edn. The Fairmont Press, Inc., U.S.A, pp23–39

Google Scholar  

Kerimray A, Bektineyev R, Rojas-Solórzano LR (2016) Energy efficiency options for buildings: Insights from buildings energy audit reports in Kazakhstan. In: 4th IET clean energy and technology conference (CEAT 2016), Kuala Lumpur, pp1–6

Singh H, Seera M, Idin MAM (2012, Dec) Electrical energy audit in a Malaysian university-a case study. In: 2012 IEEE international conference on power and energy (PECon). IEEE, pp 616–619

Wang X, Huang C, Cao W (2010, March) Energy audit of building: a case study of a commercial building in Shanghai. In: 2010 Asia-Pacific power and energy engineering conference. IEEE, pp 1–4

Khan BH (2006) Non-conventional energy resources. Tata McGraw-HillEducation

Rafiuddin N, Al Saif MY, Ahmad A (2018, Sept) WIND ARRAY: a novel approach to low speed wind harnessing. In: 2018 International conference on computing, power and communication technologies (GUCON). IEEE, pp 578–580

Download references

Acknowledgements

Authors are thankful to Mr. Mohammad Shoeb Alam and Mr. Jamil Khan for their whole hearted support in carrying out practical aspects of this work which would not be possible otherwise .

Author information

Authors and affiliations.

Aligarh Muslim University, Aligarh, UP, 202002, India

Hamad Khan, Akif Siddiqui, Aqeel Ahmad Ansari & Nidal Rafiuddin

You can also search for this author in PubMed   Google Scholar

Corresponding author

Correspondence to Hamad Khan .

Editor information

Editors and affiliations.

Department of Electrical Engineering, Qatar University, Doha, Qatar

ICE Division, NSUT Delhi, New Delhi, Delhi, India

Hasmat Malik

Department of Electrical Engineering, BGSB University, Rajouri, Jammu and Kashmir, India

Ahmed Riyaz

Faculty of Science and Technology, University of Djelfa, Djelfa, Algeria

Kouzou Abdellah

Energy Centre, Qatar Environment and Energy Research Institute, Doha, Qatar

Sertac Bayhan

Rights and permissions

Reprints and permissions

Copyright information

© 2021 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.

About this paper

Cite this paper.

Khan, H., Siddiqui, A., Ansari, A.A., Rafiuddin, N. (2021). Energy Audit in an Indian University—A Case Study. In: Iqbal, A., Malik, H., Riyaz, A., Abdellah, K., Bayhan, S. (eds) Renewable Power for Sustainable Growth. Lecture Notes in Electrical Engineering, vol 723. Springer, Singapore. https://doi.org/10.1007/978-981-33-4080-0_55

Download citation

DOI : https://doi.org/10.1007/978-981-33-4080-0_55

Published : 21 April 2021

Publisher Name : Springer, Singapore

Print ISBN : 978-981-33-4079-4

Online ISBN : 978-981-33-4080-0

eBook Packages : Energy Energy (R0)

Share this paper

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

  • Publish with us

Policies and ethics

  • Find a journal
  • Track your research

IMAGES

  1. Proposal on Energy Audit Narrative Essay Example

    research paper on energy audit

  2. Energy Audit Process

    research paper on energy audit

  3. (PDF) Energy Conservation, Efficiency & Energy Audit

    research paper on energy audit

  4. Energy Audit

    research paper on energy audit

  5. 10+ Energy Audit Report Templates

    research paper on energy audit

  6. (PDF) Electrical Energy Audit and Conservation

    research paper on energy audit

VIDEO

  1. Webinar Energy Audits

  2. CA Final Audit Paper Review May 2024

  3. Define Energy Audit

  4. Urban waste to resource recovery and recycling for energy

  5. To conduct an energy use audit

  6. How to Use Energy Audit Instruments Effectively by Mr Ravindar M Datar ,AEA,BEE #energymanagement

COMMENTS

  1. Review on Energy Audit: Benefits, Barriers, and Opportunities

    Accepted: December 20, 2022. Published: December 24, 2022. Energy audit is one lever to reduce carbon emissions of an organization (industrial site, residential building etc.;). This paper ...

  2. PDF Energy Auditing: An Overview and Key Issues

    An energy audit is an inspection, survey and analysis of energy flows for identification of energy savings opportunities in a building, process or system to reduce the amount of energy input into the system, without negatively affecting the output(s) [1]. Energy wastage is cause by inefficient energy use and lack of awareness among users.

  3. energy audit Latest Research Papers

    Financial Loss . Variable Frequency Drive . Power Plant Boiler . Plant Boiler. A reporting of Energy Audit in 2018 by LEMTEK UI has reported that air fan system currently used in Power Plant of PLTU Tanjung Jati B Jepara is inefficient, energy efficiency in FDF is only 32% and PAF efficiency is 49.01%. Inefficiency of the air fan system is an ...

  4. Energy Auditing and Conservation for Educational Buildings ...

    This paper introduces shortcut and effective approaches for energy auditing and conservation for educational buildings with application to Princess Sumaya University for Technology. The building electricity is significantly covered by a photovoltaic system, which is included in the building assessments and solutions. The short and simplified computations of the Normalized Performance Indicator ...

  5. PDF Chapter 3 Energy Audit

    An energy audit is a supervision, surveillance, and analysis of energy flowage for energy preservation in a system, process, or building to decrease energy input amount to the system, without losing or harming any output or product amount. It is a series of study performed to increase the energy efficiency, which consists of the steps like ...

  6. Energies

    The Renovation Wave for Europe highlighted the role of the public building stock for which Directive 2012/27/EU has set an annual renewal rate of 3%, which should rise to reach the goal of decarbonization by 2050. In this paper, the energy retrofit of an educational building—at the academic level—in Southern Italy was investigated.

  7. Industrial Energy Audit Methodology for Improving Energy Efficiency

    Based on literature research, there are few publications on the methods of the implementation of the energy audit in the Moroccan industries. The results obtained from the studies carried out so far have been fairly consistent and prove that there is a reduction in industrial consumption which is easily achievable and profitable thanks to the ...

  8. The impact of mandatory energy audits on building energy use

    Here we examine the effect of a large-scale mandatory audit policy—New York City's Local Law 87—on building energy use, using detailed audit and energy data between 2011 and 2016 for ...

  9. Research paper A high accurate user-friendly energy audit platform of a

    This study explores the compelling reasons why AI is needed in energy audits to revolutionize our approach to sustainable energy practices. This paper presents the development of an electrical energy audit application using MATLAB® R2020a platform, to display the energy consumption in the selected building of one State University in the ...

  10. Energy Auditing and Conservation for Educational Buildings: a Case

    The research in energy auditing and conservation may be initiated by a center in one engineering discipline with interdisciplinary collaborations with other programs, but the research outcomes and usefulness go beyond the boarders of any one of these disciplines alone. ... In this paper, a simplified energy audit has been conducted on the PSUT ...

  11. Energy conservation through energy audit

    Day by day, energy demand keeps rising so that it is essential to reduce energy consumption for that energy conservation is needed. For Conservation of energy the best option is energy audit. Energy audit is a process to determine when, where, why and how energy is used in a plant or building. Collection of these information helps to identify the situation where there is need to improve energy ...

  12. Energy Audit of an Industrial Site: A Case Study

    This paper presents the results of a preliminary energy audit carried out on 8 large industrial buildings of a famous car manufacturing holding in Italy. Energy demand for heating varied from 6 to just over 74 kWh/m3year among the buildings of the site.

  13. Energy Audit in Buildings for Sustainable Economic Development

    Abstract. Building sector consumes 40% of energy, 60% of electricity, and 25% of global water. Hot humid countries consume 46% electricity for cooling in summer and 47% gas for heating in winter. Buildings consume 40% of the world's energy resources and contribute 33% of global GHG emissions. Buildings with HVAC systems, lacking heat recovery ...

  14. PDF ENERGY AUDIT AND Its RECOMMENDATIONS

    Energy Audit is "The verification, monitoring and analysis of use of energy including submission of technical report ... JETIRDJ06025 Journal of Emerging Technologies and Innovative Research (JETIR) www.jetir.org 171 As the first step in this regard, 1 team of total 3 students is formed and was assigned a particular area or ...

  15. Investigation of the Energy Audit Practice in India

    A gap analysis of India audit programme compared to the international practice is also addressed and focus on the various government policy, energy audit standard, tool and technique applied to the HVAC system and the Lighting system is discussed in this paper. The Energy Auditing for a day is the list of the utilization which standardizes the ...

  16. Energy Audit: A Case Study

    This paper presents such energy saving methods in a methodological approach, experienced during a detailed energy audit of a medium scale apparel industry in Sri Lanka. The energy consumption and savings assessed in term of equipments used and functional areas occupied. Investing to improve the energy efficiency of a textile industry provides ...

  17. Energy Audit in an Indian University—A Case Study

    1 Introduction. This paper presents an energy audit of all buildings of hall of residents in Aligarh Muslim University (AMU) accompanying numerous rooms for residing students. AMU provides residences to around 20,000 students in nineteen halls of residences among which Nadeem Tarin hall is one.